Test Code SCOF3 Severe Acute Respiratory Syndrome Coronavirus 2 (SARS CoV-2) and Influenza Virus Type A and Type B RNA, Molecular Detection, PCR, Varies
Specimen Required
Preferred:
Specimen Type: Nasopharyngeal swab
Container/Tube: Sterile container with viral transport media
Specimen Volume: Entire specimen with a minimum of 1.5 mL (maximum 3 mL) of transport media.
Collection Instructions:
1. Collect specimen by swabbing back and forth over mucosa surface to maximize recovery of cells.
2. Swab must be placed into viral transport media (eg, M4-RT, M4 or M5), saline, or phosphate buffered saline (PBS). Media should not contain guanidine thiocyanate (GTC).
Specimen Type: Bronchoalveolar lavage fluid
Container/Tube: Sterile container
Specimen Volume: 0.6 mL
Additional Information: Do not aliquot into viral transport media.
Acceptable:
Specimen Types: Oropharyngeal (throat) swab, nasal mid-turbinate, or nares/nasal swab
Supplies:
-Culturette (BBL Culture Swab) (T092)
-Mid Turbinate (MT) Swab (FLOQSwab/COPAN) (T864)
-Swab, Sterile Polyester (T507)
Container/Tube: Sterile container with transport media
Specimen Volume: Entire specimen with a minimum of 1.5 mL (maximum 3 mL) of transport media.
Preferred: BBL Culture Swab, COPAN Mid-turbinate Swab
Acceptable: Dacron-tipped swab with plastic handle
Collection Instructions: Swab must be placed into viral transport media (eg, M4-RT, M4, or M5), saline, or PBS. Media should not contain guanidine thiocyanate (GTC).
Specimen Types: Bronchial washings, endotracheal aspirate, sputum
Container/Tube: Sterile container
Specimen Volume: 0.6 mL
Additional Information: Do not aliquot into viral transport media.
Secondary ID
622027Useful For
Simultaneous detection and differentiation of SARS-CoV-2 (cause of COVID-19), influenza A virus, and influenza B virus in upper or lower respiratory tract specimens from individuals with flu-like illnesses
Testing Algorithm
For information see Coronavirus Disease 2019 (COVID-19), Influenza, and Respiratory Syncytial Virus Testing Algorithm.
Method Name
Multiplex Reverse Transcriptase, Real-Time Polymerase Chain Reaction (RT-qPCR)
Reporting Name
SARS-CoV-2 and Influenza A/B PCR, VSpecimen Type
VariesSpecimen Minimum Volume
Upper respiratory tract swab: See Specimen Required; lower respiratory specimens: 0.3 mL
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Varies | Frozen (preferred) | 14 days | |
Refrigerated | 72 hours |
Reject Due To
Bloody specimens Calcium alginate-tipped swab Wooden swab Dry swab Glass transport tubes Transport swab containing gel or charcoal additive Transport media tubes containing the entire swab Sample tubes containing guanidine isothiocyanate, guanidine thiocyanate, or guanidine hydrochloride |
Reject |
Reference Values
Undetected
Day(s) Performed
Monday through Sunday
Report Available
Same day/1 to 2 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test has been modified from the manufacturer's instructions. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
87636
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
SCOF3 | SARS-CoV-2 and Influenza A/B PCR, V | 95422-2 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
SCOS3 | SARS-CoV-2 & Flu A/B, Source | 31208-2 |
622028 | Influenza A virus PCR | 92142-9 |
622029 | Influenza B virus PCR | 92141-1 |
622030 | SARS CoV-2 RNA, PCR | 94500-6 |